Component Mass Balance - Node ExampleFigure 269: Component Balance - Node example

Mass and component balance is performed on the node above with components A, B, C. The measured values and the results are listed in the table below.

Component Mass Balance - Node Example

FlowMeasurementToleranceReconciled Value
F11100 ton22 ton
A0.7.0070.733
B0.150.0030.1568
C0.150.0030.1102
P1440 ton8.8 ton
A0.80.0160.7917
B0.10.0020.0997
C0.10.0020.1086
P2600 ton12 ton
A0.70.0140.6901
B0.20.0140.1984
C0.10.0040.1114